Technobytes AudioWave has stopped working

Par selios2000

Hero (550)

Portrait de selios2000

14-09-2022, 20:32

Hi all.
I thought that my Zemmix Neo was "broken" because it freezed after the logo or simply showed a black screen at start up. But I realized that the problem was caused by the AudioWave cartridge. Once I removed it, the Zemmix worked out perfectly as always. No matter in what slot the cartridge is inserted. It is so rare...

!login ou Inscrivez-vous pour poster

Par ducasp

Hero (608)

Portrait de ducasp

14-09-2022, 21:25

Looks like it is activating the INTERRUPT or WAIT signal on the bus...

Par selios2000

Hero (550)

Portrait de selios2000

14-09-2022, 21:42

Ummmm... I cannot solve the problem, right? Thank you for answering.

Par selios2000

Hero (550)

Portrait de selios2000

03-10-2022, 15:17

SOLVED.
Technobytes send me the file containing the bios and with the Zemmix Neo I've been able to repair it flashing the bios again.
I'm very happy!